Last edited by Grokazahn
Sunday, August 16, 2020 | History

2 edition of Probabilistic assessment of off-normal emissions from hazardous waste incinerators found in the catalog.

Probabilistic assessment of off-normal emissions from hazardous waste incinerators

Zeng, Yi.

Probabilistic assessment of off-normal emissions from hazardous waste incinerators

a dissertation submitted in partial satisfaction of the requirements for the degree Doctor of Philosophy in Engineering

by Zeng, Yi.

  • 274 Want to read
  • 17 Currently reading

Published by University Microfilms International in Ann Arbor, Mich .
Written in English

    Subjects:
  • Incinerator emissions -- Pollution -- Control.,
  • Air -- Pollution -- Control -- Research.,
  • Hazardous wastes -- Incineration -- Research.

  • Edition Notes

    Statementby Yi Zeng.
    The Physical Object
    Paginationxvi,240p. :
    Number of Pages240
    ID Numbers
    Open LibraryOL19477906M

    Older areas, such as hazardous waste site ranking and remediation, air emissions dispersion modeling and exposure assessment, transportation safety, seismic and nuclear risk assessment, and occupational safety in the chemical industry, have continued to receive new treatments and to benefit from advances in quantitative risk assessment methods. Oppelt, E.T., , Performance Assessment of Incinerators and High Temperature Industrial Processes for Disposing of Hazardous Waste in the United States, in Lorenzen, etal. eds. “Hazardous and Industrial Solid Waste Testing and Disposal”, ASTM # , Philadelphia Google Scholar.

    Human Health Risk Assessment Protocol References September U.S. EPA Region 6 U.S. EPA Multimedia Planning and Permitting Division Office of Solid Waste Center for Combustion Science and Engineering R-3 Beckvar, N., J. Field, S. Salazar; et al. Contaminants in Aquatic Habitats at Hazardous Waste Sites: Mercury. Preliminary Analysis of Off-Normal Emissions from a Hazardous Waste Incinerator. Yi Zeng, David Okrent. Pages Estimating Emissions from Municipal Solid Waste Incinerators. Paul C. Siebert. Pages The Role of Structure-Activity Relationships in Risk Assessment Use of risk assessment methods for risk management continued to.

    This paper discusses the use of probabilistic approaches, such as Monte Carlo techniques, to quantify the uncertainty in the human health risk assessment process. Case studies include the evaluation of emissions from an existing commercial hazardous waste incinerator, an. Keywords. Assessment of off-normal emissions from hazardous waste incinerators Journal of Hazardous Materials, Vol. 26, No. 1 A correlation of emissions from laboratory and pilot scale thermal decomposition of an organic compound mixture.


Share this book
You might also like
Who killed Sir Harry Oakes?

Who killed Sir Harry Oakes?

Exercises and Experiments in Physics (Modern Physics)

Exercises and Experiments in Physics (Modern Physics)

Bibliography of literature: Puget Sound marine environment

Bibliography of literature: Puget Sound marine environment

Oklahoma peach tree survey--1998

Oklahoma peach tree survey--1998

Final report - Civil Litigation Task Force, Advocates Society.

Final report - Civil Litigation Task Force, Advocates Society.

Kirschenzeit mit Rubinella .

Kirschenzeit mit Rubinella .

[Flower arrangement projects].

[Flower arrangement projects].

world of guidance, educational and vocational

world of guidance, educational and vocational

XVII National NMR Symposium abstracts

XVII National NMR Symposium abstracts

Jacobs vow, or, Mans felicity and duty

Jacobs vow, or, Mans felicity and duty

Reform in China and its implications for the United States

Reform in China and its implications for the United States

Elements of Hindu iconography

Elements of Hindu iconography

Atomic energy

Atomic energy

Probabilistic assessment of off-normal emissions from hazardous waste incinerators by Zeng, Yi. Download PDF EPUB FB2

Journal of Hazardous Materials, 26 () 63 Elsevier Science Publishers By., Amsterdam Assessment of off-normal emissions from hazardous waste incinerators Part II: Assessment of off-normal emission intensity and total emission Yi Zeng and David Okrent Mechanical, Aerospace, and Nuclear Engineering Department, Boelter Hall, University of Cited by: 2.

Zeng and D. Okrent, Assessment of Off-normal Emission Frequency of A Hazardous Waste Incinerator, in Proceedings of PSA’89 International Topical Meeting on Probability Reliability and Safety Assessment, pp. Pittsburgh, April 2–7, Google ScholarAuthor: Yi Zeng, David Okrent.

This is the first of two papers which report the results of a study of off-normal emissions from operation of a liquid injection hazardous waste incin Cited by: 2. Hence, it appears that for modern liquid injection incinerators, designed and operated according to the assumptions of this study, the off-normal emissions for any emission category may not be.

Abstract. The papers in this book were prepared for the international topical meeting, PSA Included are the following papers: Methodology for the identification and screening of chemical and petrochemical initiating events; Probabilistic risk criteria and their application to nuclear chemical plant design; Assessment of off-normal emission frequency of a hazardous waste incinerator.

A. KarademirHealth risk assessment of PCDD/F emissions from a hazardous and medical waste incinerator in Turkey Environment International, 30 (), pp.

A.C. CullenThe sensitivity of probabilistic risk assessment results to alternative model structures: a case study of municipal waste incineration J. Air Waste. A multimedia risk assessment procedure was conducted to determine the fate and transport of polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran (PCDD/F) emissions from the Izmit Hazardous and Medical Waste Incinerator (IZAYDAS) in Turkey and their potential health er concentrations in ambient air and their deposition rates were determined by an air.

Furnace Types. Table lists the types of furnaces used for municipal solid-waste, hazardous-waste, and medical-waste incineration. Municipal solid-waste furnace designs have evolved over the years from simple batch-fed, stationary refractory hearth designs to continuous feed, reciprocating (or other moving, air-cooled) grate designs with waterwall furnaces for energy recovery.

Operators of hazardous-waste incinerators must obtain an operating permit from either federal or state regulators under standards promulgated by EPA. The permitting process for a new hazardous-waste incinerator generally takes at least 3 years and entails the investment of $ million (Steverson ). @article{osti_, title = {Sensitivity of probabilistic risk assessment results to alternative model structures.

A case study of municipal waste incineration}, author = {Cullen, A C and Harvard Center for Risk Analysus, Boston, MA}, abstractNote = {In this analysis, human health risk due to exposure to municipal waste incinerator emissions is assessed as an example of the application of.

A health risk assessment of long-term emissions of carcinogenic and non-carcinogenic air pollutants has been carried out for the municipal solid waste incinerator (MSWI) of the city of Taranto, Italy. @article{osti_, title = {Risk assessment and incineration}, author = {Pirages, S W}, abstractNote = {This paper presents an overview of the elements comprising a comprehensive risk assessment.

If the Environmental Protection agency (EPA) continues to implement its Combustion Strategy for hazardous waste combustion facilities and begins to require indirect risk assessments for municipal. In this analysis, human health risk due to exposure to municipal waste incinerator emissions is assessed as an example of the application of probabilistic techniques (e.g., Monte Carlo or Latin.

The lead emissions of incinerators are highly variable (see Chapter 4, Table and Tableand this is reflected in the facts that the mean value of lead emissions from hazardous-waste incinerators is times the median value and that the estimated range of air concentrations due to emissions varies by more than 8 orders of magnitude.

Probabilistic Causality and Its Applications to Risk Analysis.- A Comprehensive Risk Analysis Example.- Public Perception and Response to the Parkfield California Earthquake Prediction.- Preliminary Analysis of Off-Normal Emissions from a Hazardous Waste Incinerator.- Estimating Emissions from Municipal Solid Waste Incinerators Today, hundreds of incinerators are used to burn municipal solid waste (MSW) and hazardous waste.

Emissions from these incinerators are subject to regulations promulgated through the Clean. Probabilistic Assessment of Off-Normal Emissions from a Rotary KILN Hazardous Waste Incinerator Y.

Zeng and D. O/atent. REGULATORY APPLICATIONS OF PSA. II Chair: D. Dube, Northeast Utilities. The Use of Probabilistic Safety Analysis in the Regulation of Nuclear Power in the UK CH. Shepherd. Use of a PRA for Nuclear Plant Operating Configuration. The incineration of 1 ton of waste emitted, on average, μg of PCDDs/DFs and μg of dioxin-like PCBs from small municipal waste incinerators and μg of PCDDs/DFs and μg of.

@article{osti_, title = {A risk assessment of direct and indirect exposure to emissions from a proposed hazardous waste incinerator in Puerto Rico}, author = {Hallinger, K and Huggins, A and Warner, L}, abstractNote = {An Indirect Exposure Assessment (IEA) was conducted, under USEPA`s RCRA Combustion Strategy, as part of the Part B permitting process for a proposed hazardous waste.

Incineration has been used widely for waste disposal, including household, hazardous, and medical waste--but there is increasing public concern over the benefits of combusting the waste versus the health risk from pollutants emitted during combustion.

Waste Incineration and Public Health informs the emerging debate with the most up-to-date information available on incineration, pollution, and.Most risk assessment documents for waste-incineration facilities have been assembled mainly to comply with regulatory requirements and guidelines.

There is even now an EPA document that attempts to formalize some of the requirements for risk assessments for hazardous-waste incinerators .Probabilistic Causality and Its Applications to Risk Analysis.- A Comprehensive Risk Analysis Example.- Public Perception and Response to the Parkfield California Earthquake Prediction.- Preliminary Analysis of Off-Normal Emissions from a Hazardous Waste Incinerator.- Estimating Emissions from Municipal Solid Waste Incinerators